Working at Pico we are very lucky to ‘experiment’ with several prototype accessories as part of ongoing research to see what does and does not work. Here is one such example, a BMW X5 40E PHEV with an intermittent HV insulation fault that was eventually pinned down to the HV A/C compressor thanks to a supporting DTC 801252 and the Pico Insulation tester when the fault occurred (note: other DTCs were also present).
The word “intermittent” always sits heavy on your shoulders when committing to a repair based on the evidence obtained during diagnosis and with HV systems, we appear to be heavily reliant upon serial data; surely there must be another way?
Thinking about how we tackle intermittent faults, we always opt for minimal intrusions with the ‘suspect’ system underload in its normal operating environment.
With this in mind, using a prototype HV breakout cable for the A/C compressor which includes 4 mm banana sockets for the HV+ & HV- and a cable loop for a current clamp, we have the perfect solution to obtain live measurements with the compressor underload in its normal operating environment.
Now, I think we can agree, HV “LIVE” working commands all the relevant PPE and applicable training to ensure the safety of everyone and the test below is a typical example.
Given we are measuring the supply voltage to the A/C compressor (HV+ & HV-) there is only one probe to use, a HV differential probe of which we have 3 options:
Note: Option 1 above is for BNC+ Scopes only
Regarding HV current measurements, we can use our existing range of clamps where I have opted for the BNC+ 60 A clamp here.
Moving onto the capture below, we can see how the voltage to the compressor remains fixed at approx. 388 V but the current appears to be pulsed (See scope view 1).

Zooming into the current pulses (Scope view 2 above) we can see the sporadic nature of the current with a peak value of over 33 A! If we pause for a moment here, think of the power produced (momentarily) in an attempt to rotate the AC compressor (V x A: 388 x 33 = 12,804 W or 12.804 kW!)
Something is clearly not right (see image below) and we have confirmed the source of our intermittent DTC 801252.

Long story short, the compressor and condenser were replaced and the entire AC system flushed to remove contamination circulated as a result of damage to pumping components.
It is worth noting that whilst the A/C system was inoperative, the HV battery thermal management was also not working as the battery temperature is managed by the A/C system, so making air conditioning far more than a “nice to have” luxury.
Below we have the post fix test results with peak current at 5.926 A accompanied with uniformity we can attribute to pumping load, and a DC power value (between the time rulers) of 1.188 kW, a reduction of 90% prior to fix.

Note above, I have also used the BNC+ pressure transducer (channels A & B) connected to the A/C HP & LP charge ports (using experimental adapters) which allows for monitoring of the A/C system and the integrity of the compressor.
Note: The peak operating pressure of the BNC+ pressure transducer is 14 bar which an A/C system can exceed depending on design, load and ambient temperature. These transducers were used to provide feedback on the A/C system performance where the values below 14 bar can be relied upon (It is also nice to graph A/C pressures).
s a final check (and perhaps over-kill now the issue is resolved) I wanted to check the condition of the A/C compressor windings given the damage we can see above in Figure 2. Here we use the Milliohm & Motor Tester.

Note: Access to the above windings is only possible after dismantling the A/C compressor but I think we can agree winding “balance” has certainly failed.
I hope the above helps, take care...Steve